Extract, Transform, and Load SingleStore Data in Informatica PowerCenter



Create a simple Workflow for SingleStore data in Informatica PowerCenter.

Informatica provides a powerful, elegant means of transporting and transforming your data. By utilizing the CData ODBC Driver for SingleStore, you are gaining access to a driver based on industry-proven standards that integrates seamlessly with Informatica's powerful data transportation and manipulation features. This tutorial shows how to create a simple Workflow in Informatica PowerCenter to extract SingleStore data and load it into a flat file.

Add SingleStore as an ODBC Data Source

If you have not already, install the driver on the PowerCenter server and client machines. On both machines, specify the connection properties in an ODBC DSN (data source name). This is the last step of the driver installation. You can use the Microsoft ODBC Data Source Administrator to create and configure ODBC DSNs.

The following connection properties are required in order to connect to data.

  • Server: The host name or IP of the server hosting the SingleStore database.
  • Port: The port of the server hosting the SingleStore database.
  • Database (Optional): The default database to connect to when connecting to the SingleStore Server. If this is not set, tables from all databases will be returned.

Connect Using Standard Authentication

To authenticate using standard authentication, set the following:

  • User: The user which will be used to authenticate with the SingleStore server.
  • Password: The password which will be used to authenticate with the SingleStore server.

Connect Using Integrated Security

As an alternative to providing the standard username and password, you can set IntegratedSecurity to True to authenticate trusted users to the server via Windows Authentication.

Connect Using SSL Authentication

You can leverage SSL authentication to connect to SingleStore data via a secure session. Configure the following connection properties to connect to data:

  • SSLClientCert: Set this to the name of the certificate store for the client certificate. Used in the case of 2-way SSL, where truststore and keystore are kept on both the client and server machines.
  • SSLClientCertPassword: If a client certificate store is password-protected, set this value to the store's password.
  • SSLClientCertSubject: The subject of the TLS/SSL client certificate. Used to locate the certificate in the store.
  • SSLClientCertType: The certificate type of the client store.
  • SSLServerCert: The certificate to be accepted from the server.

Connect Using SSH Authentication

Using SSH, you can securely login to a remote machine. To access SingleStore data via SSH, configure the following connection properties:

  • SSHClientCert: Set this to the name of the certificate store for the client certificate.
  • SSHClientCertPassword: If a client certificate store is password-protected, set this value to the store's password.
  • SSHClientCertSubject: The subject of the TLS/SSL client certificate. Used to locate the certificate in the store.
  • SSHClientCertType: The certificate type of the client store.
  • SSHPassword: The password that you use to authenticate with the SSH server.
  • SSHPort: The port used for SSH operations.
  • SSHServer: The SSH authentication server you are trying to authenticate against.
  • SSHServerFingerPrint: The SSH Server fingerprint used for verification of the host you are connecting to.
  • SSHUser: Set this to the username that you use to authenticate with the SSH server.

Create an ETL Workflow in PowerCenter

Follow the steps below to create a workflow in PowerCenter to pull SingleStore data and push it into a flat file.

Create a Source Using the ODBC Driver

  1. In the powrmart.ini file found in %INFA_HOME%\clients\PowerCenterClient\client\bin, add the following line to the ODBCDLL section:
    CData=PMODBC.DLL
  2. In PowerCenter Workflow Manager, add a new ODBC relational connection, set the user name and password properties to the user for the machine on which the ODBC Driver is installed, and set the connect string to the System DSN for the driver (CData SingleStore Sys).
  3. In PowerCenter Designer, connect to your repository and open your folder.
  4. Select the Source Analyzer, click the sources menu, and select Import from Database...
  5. In the drop-down menu for ODBC data source, select the DSN you previously configured (CData SingleStore Sys).
  6. Click connect and select the tables and views to include.
  7. Click OK.

Create a Flat File Target Based on the Source

  1. Select the Targets Analyzer and drag and drop the previously created source onto the workspace. Using the existing source copies the columns into the target.
  2. Right-click the new target, click edit, and change the database type to flat file.

Create a Mapping to Between SingleStore Data and a Flat File

  1. Click on the Mapping Designer.
  2. Drag the source and target to the workspace (name the new mapping, if prompted).
  3. Right-click on the workspace and select Autolink by Name.
  4. Drag the columns from the source qualifier to the target definition.
  5. Save the folder (Ctrl + S).

Create Workflow Based on the Mapping

With the source, target, and mapping created and saved, you are now ready to create the workflow.

  1. Right-click the mapping and select generate workflow to open the Workflow Generation wizard.
  2. Create a workflow with a non-reusable session.
  3. Ensure that you have properly configured the connection object (to the relational connection we created earlier) and set the prefixes.
  4. Configure the Connection as needed.
  5. Review the Workflow and click Finish.

With a workflow created, you can open the PowerCenter Workflow Manager to access and start the workflow, quickly transferring SingleStore data into a flat file. With the ODBC Driver for SingleStore, you can configure sources and targets in PowerCenter to integrate SingleStore data into any of the elegant and powerful features in Informatica PowerCenter.