Build a Simple VCL Application for Okta Data



How to build a simple VCL Application to view Okta data in RAD Studio using the CData ODBC Driver for Okta.

Embarcadero RAD Studio provides a development environment for Delphi and C++Builder applications. With the CData ODBC Driver for Okta, you gain access to live Okta data within RAD Studio, abstracting the data into tables, views, and stored procedures that can be used to retrieve Okta data. This article will walk through connecting to Okta and creating a simple VCL application with the Form Designer.

Create a Connection to Okta Data

If you have not already, first specify connection properties in an ODBC DSN (data source name). This is the last step of the driver installation. You can use the Microsoft ODBC Data Source Administrator to create and configure ODBC DSNs.

To connect to Okta, set the Domain connection string property to your Okta domain.

You will use OAuth to authenticate with Okta, so you need to create a custom OAuth application.

Creating a Custom OAuth Application

From your Okta account:

  1. Sign in to your Okta developer edition organization with your administrator account.
  2. In the Admin Console, go to Applications > Applications.
  3. Click Create App Integration.
  4. For the Sign-in method, select OIDC - OpenID Connect.
  5. For Application type, choose Web Application.
  6. Enter a name for your custom application.
  7. Set the Grant Type to Authorization Code. If you want the token to be automatically refreshed, also check Refresh Token.
  8. Set the callback URL:
    • For desktop applications and headless machines, use http://localhost:33333 or another port number of your choice. The URI you set here becomes the CallbackURL property.
    • For web applications, set the callback URL to a trusted redirect URL. This URL is the web location the user returns to with the token that verifies that your application has been granted access.
  9. In the Assignments section, either select Limit access to selected groups and add a group, or skip group assignment for now.
  10. Save the OAuth application.
  11. The application's Client Id and Client Secret are displayed on the application's General tab. Record these for future use. You will use the Client Id to set the OAuthClientId and the Client Secret to set the OAuthClientSecret.
  12. Check the Assignments tab to confirm that all users who must access the application are assigned to the application.
  13. On the Okta API Scopes tab, select the scopes you wish to grant to the OAuth application. These scopes determine the data that the app has permission to read, so a scope for a particular view must be granted for the driver to have permission to query that view. To confirm the scopes required for each view, see the view-specific pages in Data Model < Views in the Help documentation.

You can then follow the steps below to use the Data Explorer to create a FireDAC connection to Okta data.

  1. In a new VCL Forms application, expand the FireDAC node in the Data Explorer.
  2. Right-click the ODBC Data Source node in the Data Explorer.
  3. Click Add New Connection.
  4. Enter a name for the connection.
  5. In the FireDAC Connection Editor that appears, set the DataSource property to the name of the ODBC DSN for Okta.

Create VCL Applications with Connectivity to Okta Data

Follow the procedure below to start executing queries to Okta data from a simple VCL application that displays the results of a query in a grid.

  1. Drop a TFDConnection component onto the form and set the following properties:

    • ConnectionDefName: Select the FireDAC connection to Okta data.
    • Connected: Select True from the menu and, in the dialog that appears, enter your credentials.
  2. Drop a TFDQuery component onto the form and set the properties below:

    • Connection: Set this property to the TFDConnection component, if this component is not already specified.
    • SQL: Click the button in the SQL property and enter a query. For example:

      SELECT Id, ProfileFirstName FROM Users WHERE Status = 'Active'
    • Active: Set this property to true.
  3. Drop a TDataSource component onto the form and set the following property:

    • DataSet: In the menu for this property, select the name of the TFDQuery component.
  4. Drop a TDBGrid control onto the form and set the following property:

    • DataSource: Select the name of the TDataSource.
  5. Drop a TFDGUIxWaitCursor onto the form — this is required to avoid a run-time error.

You now have an executable application that displays the results of the SQL Query set in the TFDQuery object.

Related Articles

Below you can find other articles for using the CData ODBC Driver with RAD Studio, Delphi, and C++ Builder.

Ready to get started?

Download a free trial of the Okta ODBC Driver to get started:

 Download Now

Learn more:

Okta Icon Okta ODBC Driver

The Okta ODBC Driver is a powerful tool that allows you to connect with live data from Okta, directly from any applications that support ODBC connectivity.

Access Okta data like you would a database - read, write, and update Okta 0, etc. through a standard ODBC Driver interface.