Ready to get started?

Learn more:

Bullhorn CRM Connectivity Solutions

Configure a Solicit-Response Send Port for the CData BizTalk Adapter for Bullhorn CRM



Use the adapter for Bullhorn CRM with a solicit-response send port to execute updategrams and data manipulation SQL in BizTalk.

This section provides step-by-step instructions for creating, configuring, and testing a static solicit-response send port using the CData BizTalk Adapter for Bullhorn CRM. You can use a static solicit-response send port to execute commands and access the results in BizTalk. You can use send ports to execute updategram commands, SQL commands, and stored procedure operations.

Create and Configure the Send Port

Create a static solicit-response send port and configure it to use the adapter as its transport type.

  1. If you have not already done so, open your BizTalk application in the BizTalk Administration Console.
  2. In the node for your BizTalk application, right-click Send Ports and select New -> Static Solicit-Response Send Port. The Send Port Properties dialog is displayed.
  3. In the Send Port properties, enter a name for the receive port.
  4. In the Transport Type menu, select CData.BullhornCRM;.
  5. In the Send pipeline menu, select the default option, PassThruTransmit.
  6. In the Receive pipeline menu, select the default option, PassThruReceive.

Configure the Adapter

Define the command the adapter will execute in the Transport Properties dialog.

  1. In the send port properties, click the Configure button. The Adapter Transport Properties dialog is displayed.
  2. In the CommandType property, select the command type you want.
  3. If you want to execute an SQL command, enter the command in the SQL Command box.
Refer to the "Adapter Configuration" chapter in the help documentation for a description of the various properties and their functions.

Configure the Connection to Bullhorn CRM

Configure credentials and other properties required to connect to Bullhorn CRM in the Connection String Options dialog.

  1. In the send port properties, click Configure. The adapter properties dialog is displayed.
  2. Click the button in the Connection String property. The Connection String Options dialog is displayed.
  3. Enter the connection properties. Below is a typical connection string: DataCenterCode=CLS33;OAuthClientId=myoauthclientid;OAuthClientSecret=myoauthclientsecret;InitiateOAuth=GETANDREFRESH

    Begin by providing your Bullhorn CRM account credentials in the following:

    If you are uncertain about your data center code, codes like CLS2, CLS21, etc. are cluster IDs that are contained in a user's browser URL (address bar) once they are logged in.

    Example: https://cls21.bullhornstaffing.com/BullhornSTAFFING/MainFrame.jsp?#no-ba... indicates that the logged in user is on CLS21.

    Authenticating with OAuth

    Bullhorn CRM uses the OAuth 2.0 authentication standard. To authenticate using OAuth, create and configure a custom OAuth app. See the Help documentation for more information.

  4. Click Test Connection to verify the values and test connectivity.
Refer to the "Connection String Options" chapter in the help documentation for a description of the various properties and their functions. The updategram tutorial for the adapter for Bullhorn CRM walks through the steps to create a simple application that uses a solicit-response send port to execute an insert updategram to Bullhorn CRM.